3.7: Arming/Disarming
The following section explains how to arm and disarm the control panel using the LCD
keypad.
The ProGuard800 offers three arming modes that you can define to suit the application.
Figure 3.4 illustrates the three arming modes. In each diagram, the protected area is shaded.
Full Part Perimeter
Figure 3.4: Arming Modes
The arming options are entirely flexible. You can program each sensor to be included in
any combination of the three arming modes – see section 7.6.2: Arm Set. Additionally,
each arming mode has a separate exit and entry delay.
The arming functions are only available while the system is in Standby mode.
3.7.1: Arming Keys
The Arming keys enable you to arm the system using any of the three arming methods:
Full, Part and Perimeter.
Full Part Perimeter
Figure 3.5: Arming Keys
3.7.2: Full Arming
Full arming is designed for when the occupant vacates the premises.
To fully arm the system:
1. Check if the system is ready to arm.
2. Press the Full arming key on the keypad.
3. If One-Key Arming is disabled, enter your user code. See 9.3.2: One-
Key Arming
3.7.3: Part Arming
Part arming is designed for when the occupant intends to remain inside one part of the
premises and secure another part.